Jump to content
  • To Search the Seeq Knowledgebase:

    button_seeq-knowledgebase.png.ec0acc75c6f5b14c9e2e09a6e4fc8d12.png.4643472239090d47c54cbcd358bd485f.png

Search the Community

Showing results for tags 'remove'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • Community Technical Forums
    • Tips & Tricks
    • General Seeq Discussions
    • Seeq Data Lab
    • Seeq Developer Club
    • Seeq Admin Forum
    • Feature Requests

Categories

  • Seeq FAQs
  • Online Manual
    • General Information

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


Company


Title


Level of Seeq User

Found 4 results

  1. A typical data cleansing workflow is to exclude equipment downtime data from calculations. This is easily done using the .remove() and .within() functions in Seeq formula. These functions remove or retain data when capsules are present in the condition that the user supplies as a parameter to the function. There is a distinct difference in the behavior of the .remove() and .within() functions that users should know about, so that they can use the best approach for their use case. .remove() removes the data during the capsules in the input parameter condition. For step or linearly interpolated signals, interpolation will occur across those data gaps that are of shorter duration than the signal's maximum interpolation. (See Interpolation for more details concerning maximum interpolation.) .within() produces data gaps between the input parameter capsules. No interpolation will occur across data gaps (no matter what the maximum interpolation value is). Let's show this behavior with an example (see the first screenshot below, Data Cleansed Signal Trends), where an Equipment Down condition is identified with a simple Value Search for when Equipment Feedrate is < 500 lb/min. We then generate cleansed Feedrate signals which will only have data when the equipment is running. We do this 2 ways to show the different behaviors of the .remove() and .within() functions. $Feedrate.remove($EquipmentDown) interpolates across the downtime gaps because the gap durations are all less than the 40 hour max interpolation setting. $Feedrate.within($EquipmentDown.inverse()) does NOT interpolate across the downtime gaps. In the majority of cases, this result is more in line with what the user expects. As shown below, there is a noticeable visual difference in the trend results. Gaps are present in the green signal produced using the .within() function, wherever there is an Equipment Down capsule. A more significant difference is that depending on the nature of the data, the statistical calculation results for time weighted values like averages and standard deviations, can be very different. This is shown in the simple table (Signal Averages over the 4 Hour Time Period, second screenshot below). The effect of time weighting the very low, interpolated values across the Equipment Down capsules when averaging the Feedrate.remove($EquipmentDown) signal, gives a much lower average value compared to that for $Feedrate.within($EquipmentDown.inverse()) (1445 versus 1907). Data Cleansed Signal Trends Signal Averages over the 4 Hour Time Period Content Verified DEC2023
  2. I've got a signal with drop-outs and I want to filter my signal to only visualize samples with values above a threshold. Is there a quick way to do this in Seeq?
  3. Hi All, I'm trying to get a solution for the missing value imputation. Is there any ways to it like filling missing values with "Mean" or "Median". Below is the screenshot for the same. Regards, Jitesh Vachheta
  4. Hi All, I've got few Scaler values in my data-set (E.g High,On,OFF) , I have convert all of them into Capsule by toCapsule() Function. Now wanted to remove only those capsules which are having "OFF" Status. Regards, Jitesh Vachheta
×
×
  • Create New...