Jump to content
  • To Search the Seeq Knowledgebase:

    button_seeq-knowledgebase.png.ec0acc75c6f5b14c9e2e09a6e4fc8d12.png.4643472239090d47c54cbcd358bd485f.png

Search the Community

Showing results for tags 'condition'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • Community Technical Forums
    • General Seeq Discussions
    • Seeq Admin Forum
    • Training Resources
    • Product Suggestions
    • Seeq Data Lab
  • Community News
    • Seeq Blog Posts
    • News Articles
    • Press Releases
    • Upcoming Events
    • Resources

Calendars

  • Community Calendar

Categories

  • Seeq FAQs
  • Online Manual
    • General Information

Categories

  • Published
  • Code
  • Media

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


About Me


Company


Title


Level of Seeq User

  1. In some cases you may want to do a calculation (such as an average) for a specific capsule within a condition. In Seeq Formula, the toGroup() function can be used to get a group of capsules from a condition (over a user-specified time period). The pick() function can then be used to select a specific capsule from the group. The Formula example below illustrates calculating an average temperature for a specific capsule in a high temperature condition. // Calculate the average temperature during a user selected capsule of a high temperature // condition. (The high temperature condition ($Hi
  2. I have a step signal that is either always 0 or 1 (Boolean). I need to create a signal every time this value changes. Any tips to help me out here? Thanks in advance.
  3. FAQ: How do I identify time periods where I have overlapping capsules within the same condition? I may want to keep only the capsules (time periods) where capsules overlap. I may also want to keep the times where a certain number (2, 3, or more) of capsules overlap. In this example, we will find time periods where there are at least 2 overlapping capsules which make up the Event Condition. In the screenshot below, you can see there are 3 separate time periods where the Event condition capsules overlap: Step 1: Merge any overlapping capsules together using the merge() function
  4. FAQ: I have a condition for events of variable duration. I would like to create a new condition that comprises the first third of the time (or 4th, or 10th) of the original condition. Solution: A stepwise approach can be taken to achieve this functionality. 1. Begin with your condition loaded in the display pane. 2. Create a new Signal using Signal from Condition that calculates the total duration of each of your event capsules, interpolated as a step signal. 3. Create a new signal that is your total event duration multiplied by the proportion of t
  5. FAQ: I have a CSV file that has the start and end times of some historical events and various information about the events that I would like to use in my analysis in Seeq. How do I go about getting these events and all of their associated information into Seeq? Solution: Use the Import from CSV tool and Seeq Formula to bring in a condition comprised of each of these events and assign the data in each column of the CSV as a property of the condition. 1. Ensure your CSV file is formatted correctly for import into Seeq. The first column should be the event start time, the second
  6. Frequently Asked Question: Is there a way to change the color of my signals overlaid in capsule time view to highlight the different capsules? Solution: One approach to changing the color of the signal being overlaid in capsule time view is to create separate signals for each desired display color that only contain samples during specific capsule(s). The examples below provide a step-wise approach to coloring based on either logic or time. Logic Based Coloring: Scenario: We start out with a temperature signal that we are overlaying based on a daily condition. We want
  7. When examining data in Capsule Time view it can be useful to view data from the time period immediately the capsules alongside the data during the capsules. This can be done by: 1. Hover over the x-axis (shown in the image above as measuring time from the start of the capsule in hours), click and drag your mouse to the right. You will likely see no data from the time period before 0.0 on the x-axis. 2. Click on the "Dimming" option at the top of the Display Pane. Check the box to "Show Data Outside of Conditions". When this box is checked the data o
  8. Background: When looking to identify trends or step changes in a signal, we typically recommend an approach of smoothing the signal, taking the first derivative, then identifying when that derivative is positive or negative. This method works well most of the time, but employing this technique in combination with others can be more effective at capturing trends/step changes when the value change in the signal is more subtle. Solution: When looking for step changes, we can use a technique of calculating a range of the signal on a rolling periodic basis and search for when the r
  9. Background: A property can be added to capsules for further filtering and aggregation through Seeq tools, including Histogram. All properties on a condition are stored as string values. This post examines how to add a property to a condition and then how those properties may be used. Adding Properties to a Condition Capsule properties may be used to store important information such as, Product Codes, Batch IDs, and Recipes. There are three functions in Seeq Formula which can add properties to the capsules in a condition: toCondition() - Dedicated function to transform a
  10. FAQ: I've created a condition for a particular event of interest and now I would like to create a signal that is the running count of these events in a given time period. This analysis is common in equipment fatigue use cases when equipment degrades slowly based on a number of cycles (thermal, pressure, tension, etc) that it has undergone during it's life or since a last component replacement. Solution: We can convert each of these capsules into a signal comprised of a single sample (with value of 1) per capsule, then take a running sum of this new signal over the cu
  11. Contextual data is often brought into Seeq to add more information to time series data. This data tends to be brought in as a condition, with the capsule properties of this condition containing different pieces of information. In some cases, a particular capsule property may not contain just one piece of information; it may contain different pieces that are separated based on some logic or code. Rather than having users visually parse the code to extract the segments of interest, Seeq can be used to extract the substring continuously. The code below extracts a substring based on its locat
  12. I have successfully setup two (MS SQL) condition queries in the SQL Connector V2 JSON file. When I add these conditions to a trend, the last capsule shows "In Progress" in the Capsules table although the SQL does return an end date for this capsule. The capsule at the top of the trend does end at the correct time, but it is hollow as if the capsule is in progress. Any help on this would be appreciated, Andrew
  13. FAQ: For reporting purposes, I want to calculate statistics based on the current period to date and display that next to the periods immediately preceding it. This is easy to do using the custom date range tool in Organizer Topic (Creating a Periodic Condition and the grabbing the capsule closest to or offset by 1 from the end). Is there a way to create these same date ranges relevant to the current time in Seeq Workbench? Solution: We can create identical conditions in Seeq Workbench by following the methods below. The first method defines how to create conditions
  14. Question: I have a condition with multiple properties that I have displayed in the capsules pane. Is there a way to get the data from the capsules pane into a Seeq Organizer Topic? Solution: Create a new string signal for each property that you are interested in displaying in your Organizer Topic, then create a scorecard that displays those values in a table that can be added to Organizer Topic. 1. Use Formula to create a new string signal with a value equal to the capsule data for a certain property. The formula syntax to do this is: $YourCond
  15. FAQ: We have various conditions that are calculated from signals on a variety of different equipment and assets. We would like to view them in a histogram that is broken out by month, and for each month each asset has a separate bar in the histogram. Example Solution: 1. For three signals, we want to create a histogram that is the total time per month spent above some threshold. In this example, each signal is associated with a different cooling tower Area. 2. We have a condition for when each signal is above it's threshold value. These conditions were created using
  16. Overview Often times two (or more) units that the same products and unit procedures. This is common in continuous processes that are running a specific "grade"; also in batch processes that are manufacturing the same product ID. Since they are identical pieces of equipment or units, the “profiles” of critical process parameters are similar and we want to use profiles from multiple units for our reference profile. In this example we will create a profile from 2 units - the same process can be applied for additional units ad infinitum. Then we will apply this profile to a running batch to
  17. The following steps will create a prediction model for every capsule in a condition. Step 1. pick a condition with capsules that isolate the desired area of regression. Any condition with non-overlapping capsules will work as long as there are enough sample points within its duration. For this example, an increasing temperature condition will be used. However, periodic conditions and value search conditions will work as well. Step 2. Create a time counter for each capsule in the condition. This can be done with the new timesince() function in the formula tool. The timesince() fun
  18. Background: I have a sensor that shows a step change in the amplitude of the signal noise a couple of days prior to instrument failure. It would be useful to be able to identify that step change in the amplitude of the noise so that preventative maintenance can be scheduled rather than running the instrument to failure and causing an unplanned shutdown or production loss event. Solution: Use a combination of Formula and the Value Search tool to identify when this increased signal noise is occurring. Starting signal: 1. Use Seeq Formula and the runningDelta() a
  19. FAQ: How do I create a condition for operational shifts if they alternate days and hours? e.g. (The EOWeO schedule) The following solution will keep the start times the same regardless of daylight savings. So, there will be an 11-hour shift in March and a 13-hour shift in November. For areas that don’t follow daylight savings a simpler solution can be found further below. Overview: To achieve the results described above the shift() function will need to be used in order to create the desired effects around daylight savings. If there was no daylight savings the periods() function wo
  20. Hi All, I'm trying to get a solution for the missing value imputation. Is there any ways to it like filling missing values with "Mean" or "Median". Below is the screenshot for the same. Regards, Jitesh Vachheta
  21. Background In this Use Case, a user created a condition to identify when the compressor is running. During each Compressor Running capsule, the compressor operates in a variety of modes. The user would like a summary of the modes of operation for each capsule in the form of a new signal that reports all modes for each capsule (i.e. Transition;Stage 1;Transition;Stage 2;Transition, Stage 1;Transition). Method 1. The first step is to resample the string value to only have data points at the value changes. It's possible the signal is already sampled this way, but if it is
  22. You can use the start and end times of capsules to create new capsules with an arbitrary time before or after. This is useful when the process expert knows that there is a time period of interest before or after a capsule start or end timestamp. Refer to the example below. Here we have a series for the Area A Compressor Power shown in blue. We have created capsules shown in green for when the compressor is running in the high state, above 30kW. In this example, we want to create a capsule series that starts when the compressor exits the high stage (goes below 30kW) and then
  23. Background In this Use Case, a condition was created to identify when a compressor is running. Let's say I'd like to extend each capsule in this condition so that instead of ending when the compressor turns off, it ends when the next compressor running capsule starts. Method The method used depends on the Seeq version. Seeq R21.0.42 and Later Version R21.0.42 introduced the .growEnd() operator; this operator grows capsules in in a condition by extending the end until the start of the next capsule. Earlier Versions (Before R21.0.42) 1. First, cr
  24. FAQ: I would like to create a condition for the summer season that runs from May 1 - September 30, but when I use the Periodic Condition tool to create a monthly condition and select the months May-September, I get individual monthly capsules rather than one capsule for the entire summer. Is there a better way to do this using Seeq's tools? Solution 1 - Using Seeq Point & Click Tools: 1. Use the Periodic Condition tool to create a condition for May. 2. Use the Periodic Condition tool to create a condition for September. 3. Use the Composite Condition
  25. I have a Boolean signal and would like to count the number of events over a specified time period. How can this be accomplished in Seeq? Thanks, Sam
×
×